Why does my furnace igniter glow but the burners won’t light?

If your furnace igniter glows red or orange but the burners never light, the furnace is making it partway through the startup sequence but something is preventing ignition.

A glowing igniter tells you that the furnace is receiving a call for heat and that at least part of the ignition system is working. But the furnace still needs the proper gas flow, burner operation and safety signals before the burners can ignite.

Several problems can cause the igniter to glow without producing a flame.

The gas valve may not be opening

After the igniter heats up, the furnace control board should signal the gas valve to open. If the gas valve does not open, the burners will not receive fuel and cannot ignite. The problem could involve the gas valve itself, the wiring to the valve or another control issue that is preventing the valve from being energized.

Gas valve problems require professional diagnosis.

There may be a gas supply problem

The furnace may also fail to ignite if there is no gas reaching the burner assembly.

Possible causes include:

A closed gas shutoff valve

A problem with the home’s gas supply

Low gas pressure

A problem with the furnace gas valve

Another interruption in fuel delivery

If other gas appliances in the home are also not working, there may be a broader gas supply issue. If you smell gas, leave the area and contact the appropriate gas utility or emergency service from a safe location.

The igniter may glow but still be too weak

A hot surface igniter can sometimes glow without becoming hot enough to reliably ignite the gas. Igniters become more fragile as they age and can develop small cracks or electrical resistance problems. The igniter may appear to be working because it glows, but it may not be reaching the temperature needed for dependable ignition. A technician can test the igniter rather than assuming it is good based on appearance alone.

Dirty burners can interfere with ignition

The burner assembly has to allow gas to flow and ignite properly. Rust, dirt, debris or other contamination can interfere with burner operation. In some cases, gas may reach the burners but fail to ignite where it should. Burner problems can also affect how flame travels from one burner to another after ignition begins. Because burners are part of the combustion system, they should be inspected and cleaned properly rather than poked, scraped or adjusted at random.

The pressure switch may not be proving properly

Before the furnace allows normal ignition, it verifies that the venting system is operating correctly. The inducer motor creates draft through the furnace, and the pressure switch helps confirm that the furnace can safely vent combustion gases.If the pressure switch opens or fails to prove at the wrong time, the control board may interrupt the ignition sequence.

Possible causes can include:

A blocked vent or intake pipe

A weak inducer motor

Damaged pressure-switch tubing

A clogged condensate drain

A faulty pressure switch

Other venting problems

Depending on the furnace design, the igniter may still glow during part of this sequence before the startup is interrupted.

A clogged condensate drain can stop ignition

High-efficiency furnaces produce condensation during operation. If the condensate drain system becomes blocked, water can back up and interfere with pressure-switch operation or other safety controls. The furnace may begin the ignition sequence but stop before the burners light. This is one reason a glowing igniter does not automatically mean the problem is located at the igniter itself.

The control board may not be sending power to the gas valve

The furnace control board manages the entire startup sequence. Once the igniter reaches the proper temperature, the board should send power to the gas valve. If that signal is not being sent, the burners will not receive gas. The cause could be the control board itself, but it could also be another safety condition preventing the board from allowing ignition.

Proper electrical testing is needed to tell the difference.

Listen to what happens after the igniter glows

The sequence of events can provide useful clues.

A typical startup may sound like this:

The inducer motor starts

The pressure switch proves

The igniter begins glowing

The gas valve opens

The burners ignite

The blower starts after the furnace warms up

If the igniter glows and then simply shuts off without burner ignition, the problem may involve gas flow, the gas valve, a safety control or the control board. If you hear a click from the gas valve but still get no flame, that is also useful diagnostic information for the technician.

Could a dirty flame sensor cause this?

Usually, a dirty flame sensor causes a slightly different symptom. The burners typically ignite first, then shut off after a few seconds because the furnace cannot verify the flame. If the burners never light at all, the problem is more likely to involve the igniter, gas supply, gas valve, burner assembly or another part of the startup sequence.

Will the furnace keep trying?

Many furnaces will make several ignition attempts before stopping. If the burners fail to light repeatedly, the furnace may eventually go into lockout. This is a safety feature designed to prevent the system from endlessly attempting ignition. If the furnace goes into lockout, resetting it may temporarily allow another startup attempt, but it will not fix the underlying problem.

When should you call for furnace repair?

You should have the furnace inspected if:

The igniter glows but the burners never light

The furnace repeatedly attempts ignition

The furnace goes into lockout

You hear the gas valve click but get no flame

The igniter works only intermittently

The furnace has stopped heating the home

You smell gas

The problem returns after the furnace is reset

A technician can test the igniter, gas valve, gas supply, burners, safety controls and control board to determine exactly where the ignition sequence is failing.

Need help with a furnace that will not ignite?

If your furnace igniter glows but the burners will not light, the problem may involve the igniter, gas valve, gas supply, burner assembly, pressure switch or control system.

Roberts Brothers Comfort can inspect the furnace startup sequence, identify why the burners are not lighting and make the necessary repairs. We provide expert furnace repair service throughout Ohio’s Miami Valley region including Casstown, Covington, Fletcher, Piqua, Rosewood, Saint Paris, Sidney, Tipp City, Troy, Urbana, West Milton and all the surrounding areas.

Megan Purk

Piqua, OH

Awesome workers!
We got our furnace and AC installed by them! Very professional and nice. They also fixed part of a vent that had collapsed in our crawl space. Highly recommend them

Jan Palmer

Piqua, OH

Jim and I cannot be happier with Roberts Bros. Comfort!! We had a complete new HVAC system installed. Brad is professional, genuine, knowledgeable and fair… trustworthy! Gordon, Clay and Phil were amazing!! Again, professional, pleasant, knowledgeable, very clean, quiet and prompt!!  If we could give 10 stars we would!  Highly recommend this company!!

Judy Shawler

Piqua, OH

Phil was very kind and did an awesome job and explaining what he was doing. I will have your company do work for us again. Thank you

Beth Buecker

Piqua, OH

Roberts Brothers Comfort was able to come to our house the same day our furnace went out and give us an estimate. Their price, their service and their knowledgeable installers are the best! I would highly recommend them for your Furnace and A/C needs.

Keton Bolden

Piqua, OH

Robert Brothers Comfort was amazing. They got out here in a very timely manner, figured out what was the problem of my AC unit. Had the part in 2 days and were here in the pouring rain outside to fix it. I will recommend them to EVERYONE!

After hours & weekend service available

Use this form to contact us after hours

Preventative HVAC Maintenance Plans Available

For all furnace and AC systems