Why does my furnace burner keep going out?

If your furnace burners ignite but then go out before your home reaches the temperature set on the thermostat, something is interrupting the heating cycle. The cause could be as simple as a dirty flame sensor, but repeated burner shutdowns can also be related to overheating, airflow problems, ignition issues, venting problems or a failing furnace component. The timing of the shutdown can provide an important clue.

A dirty flame sensor is a common cause

If the burners light normally and then shut off after only a few seconds, the flame sensor is one of the first things that should be checked. The flame sensor confirms that the burners are actually producing a flame. If it does not detect the flame properly, the furnace control board shuts off the gas supply as a safety measure. A dirty or oxidized flame sensor may still be physically intact but unable to send a reliable signal. The furnace may then try to ignite again, only to repeat the same cycle.

The furnace may be overheating

If the burners stay on for several minutes before shutting off, overheating may be the problem. A furnace that gets too hot will normally shut the burners down to protect the system.

Common causes of overheating include:

A dirty furnace filter

Closed or blocked registers

A dirty blower wheel

A weak or failing blower motor

Restricted ductwork

An overly restrictive filter

Other airflow problems

If the furnace cools down and then starts again, this can create a repeated cycle of heating, shutting down and restarting.

A dirty filter can restrict airflow

A clogged filter is one of the easiest problems for a homeowner to check. As the filter becomes loaded with dust and debris, less air can pass through the furnace. That can cause heat to build up inside the heat exchanger. If the furnace reaches an unsafe temperature, the high-limit switch may shut the burners off. Check the filter and replace it if it is visibly dirty. If the burner problem continues after the filter is replaced, the furnace should be inspected.

The high-limit switch may be shutting the burners down

The high-limit switch is a safety device that monitors furnace temperature. If the furnace gets too hot, the switch shuts the burners off. The blower may continue running to help cool the furnace. Once the temperature drops, the burners may ignite again. A furnace that repeatedly trips the high-limit switch usually has an underlying airflow or overheating problem that needs to be corrected.

The burners may be dirty

Dirt, rust or debris can interfere with proper burner operation. The flame may become uneven, unstable or fail to travel properly across the burner assembly. This can affect ignition and may also interfere with flame sensing. Burner cleaning and adjustment should be handled carefully because the burner assembly is part of the furnace combustion system.

The gas supply may be inconsistent

The burners need a steady supply of gas to remain lit. Problems with gas pressure, the furnace gas valve or another part of the fuel supply system can cause the flame to drop out. If the gas valve is not opening correctly or gas pressure is unstable, the furnace may shut the burners down. Gas supply problems require professional diagnosis.

A venting problem can interrupt furnace operation

Gas furnaces must safely move combustion gases out of the home. Many furnaces use a pressure switch to verify that proper venting conditions exist before and during operation. If the venting system becomes blocked or the pressure switch loses its signal, the furnace may shut the burners off.

Possible causes include:

A blocked intake or exhaust pipe

A weak inducer motor

Damaged pressure-switch tubing

A clogged condensate drain

A venting restriction

A faulty pressure switch

These safety controls should not be bypassed.

A clogged condensate drain can cause problems

High-efficiency furnaces produce water as part of the combustion process. That water must drain properly. If the condensate drain, trap or tubing becomes clogged, it can interfere with pressure-switch operation and cause the furnace to shut down. This is one reason burner shutdowns are not always caused by the burner assembly itself.

The control board may be shutting the furnace down

The control board monitors the furnace’s safety systems and operating sequence. If it detects an improper flame signal, pressure-switch problem, overheating condition or another fault, it may shut the burners off. A failing control board can also cause unusual operation, although it should be tested before being replaced. Many furnaces display a diagnostic code when a fault occurs. If you can see a flashing LED through the furnace viewing window, the flash pattern may help identify what caused the shutdown.

Pay attention to how long the burners stay lit

The amount of time the burners remain on can help narrow down the problem. If the burners go out after only a few seconds, a flame sensor problem is more likely. If they run for several minutes and then shut off, overheating or airflow problems become more likely. If the burners stop and restart unpredictably, the problem could involve gas flow, venting, electrical controls or another intermittent fault. This timing information can be very useful when you describe the problem to an HVAC technician.

Is it normal for furnace burners to turn off?

Yes, but only as part of a normal heating cycle.

Once the thermostat reaches the desired temperature, the furnace should shut the burners off. The blower may continue running briefly to move the remaining heat through the ductwork. The problem is when the burners repeatedly go out before the thermostat is satisfied. That usually means the furnace is being interrupted by a safety control or another operating problem.

When should you call for furnace repair?

You should have the furnace checked if:

The burners repeatedly light and go out

The burners shut off after only a few seconds

The furnace keeps restarting

The blower runs but the burners repeatedly stop

The furnace goes into lockout

The furnace is overheating

The diagnostic light shows a recurring fault code

You smell gas or burning

Replacing the filter does not solve the problem

Repeated burner shutdowns should not be treated as normal furnace operation.

Need help with furnace burners that keep going out?

If your furnace burners keep going out, the problem may involve the flame sensor, airflow, high-limit switch, gas supply, venting system, pressure switch or another furnace control.

Roberts Brothers Comfort can inspect the furnace, determine why the burners are shutting down and make the necessary repairs. We provide expert furnace repair service throughout Ohio’s Miami Valley region including Casstown, Covington, Fletcher, Piqua, Rosewood, Saint Paris, Sidney, Tipp City, Troy, Urbana, West Milton and all the surrounding areas.

Megan Purk

Piqua, OH

Awesome workers!
We got our furnace and AC installed by them! Very professional and nice. They also fixed part of a vent that had collapsed in our crawl space. Highly recommend them

Linda Chambers

Piqua, OH

Very pleased with our experience! Brad was very good explaining what we needed and how it worked! Always arrived on time and completed the work quickly! Would highly recommend this company!

Lisa Deal

Piqua, OH

We recently had a new HVAC system installed, and the entire experience was outstanding from start to finish. Brad came out to estimate the job, and his expertise and thoroughness gave us confidence right away. Michelle kept us informed throughout the entire process, communicating every detail clearly and promptly.

When it came time for installation, our technicians, Phil and Clayton, were amazing—timely, knowledgeable, and reliable. They were faced with the challenge of replacing our original system that had been in our home for 26 years, but they found the perfect solution. Their professionalism and skill were top-notch.

Huge thanks to Brad and his team for making this a seamless experience. I highly recommend them to anyone in need of HVAC services!

Keton Bolden

Piqua, OH

Robert Brothers Comfort was amazing. They got out here in a very timely manner, figured out what was the problem of my AC unit. Had the part in 2 days and were here in the pouring rain outside to fix it. I will recommend them to EVERYONE!

Heather Monroe

Piqua, OH

I was unable to get ahold of the service I had previously used. Roberts Brothers were recommended by two different people. They were prompt and solved my problem quickly. I will most definitely call them 1st in the future.

After hours & weekend service available

Use this form to contact us after hours

Preventative HVAC Maintenance Plans Available

For all furnace and AC systems